Special Notes

To view prices, please create an account. The photograph shows our standard design. We can customize many of our appliances for your patient's specific needs - please see our auxiliaries and color chart (not applicable for nylon appliances).

LAB APPLIANCE This product is a custom lab appliance. Please choose the "Send us a Case" option on the product page or top menu bar.
Item Number
BHPX

Designed to produce orthopedic expansion of the maxilla, as well as rotate and distalize maxillary first molars with minimal involvement from the patient. The Hilgers Pendex utilizes the components of both the Haas and Quad Helix appliances.


The acrylic button is an effective anchoring component and .032 TMA* springs produce light, continuous force against the molars.


*TMA wire is a trademark of Ormco Corporation, Glendora, CA

More Information
Great Lakes Exclusive No
Medicare Accepted No
Removable No
Banded Yes
Material Type Acrylic, Stainless Steel, Titanium
Write Your Own Review
You're reviewing:Hilgers Pendex
Your Rating

Mail Traditional Models

Step 1 - Download Prescription

Hilgers Pendex Rx

Step 2 - Print a Shipping Label

Step 3 - Mail it in!

Canadian and International Customers

Ship to:

Great Lakes Dental Technologies
PO BOX 5111
Tonawanda NY 14150-5111
USA


Upload Digital Models

Option 1

Select your scanner to view easy instructions on how to submit a digital model.

Great Lakes also supports DDX, Medit, and Planmeca. If you need assistance, please contact us.

Option 2

Upload your digital models to the Great Lakes Digital Portal. It's a simple and secure way that accepts STL files from any scanner. Click here for instructions.

General Requirements

Impressions:

  • Accurate impressions with any type of impression material are acceptable
  • Impressions must adequately reflect all relevant anatomy
  • Impression material must not be separating from the impression tray
  • Consider pouring your models right away if your impressions are moisture, temperature, or time sensitive
  • Impressions sensitive to moisture content should be wrapped in a damp paper towel and placed in a sealed plastic bag if models are not poured immediately
  • Only metal impression trays and those with VPS impression material will be returned
  • The nature of impression materials currently on the market may contribute to common model problems encountered in the laboratory. Have you encountered porosity (bubbles, voids) or poor surface quality? Plaster or stone mixes are water based and they interact with impression surfaces in a water-like manner. Liquids placed on solid surfaces will be either attracted to, or repelled from that surface in varying degrees. Please be aware when selecting impression material if it is hydrophilic or hydrophobic.

Hydrophilic: is attracted to, or can be wetted by water.
Hydrophobic: is when liquid is repelled or fails to bond with liquids.
Vinyl poly siloxane (VPS) options can be hydrophilic or hydrophobic. Alginate is hydrophilic.

  • There are advantages and disadvantages to these impression options but there are products on the market to help reduce the disadvantages. Surfactants and debubblizer sprays can be used to lower surface tension between surfaces making the impression material more hydrophilic and assure a better impression result.
  • Great Lakes carries ACU-flow™ a VPS impression material which is hydrophilic and requires NO surfactant spray for surface tension reduction, eliminating bubble formation. Surfactants must be used properly and excess surfactant should not be allowed to pool in the cusp tips. This can cause loose, sandy-like cusp tips. Excess surfactant needs to be blown out leaving a wet look only before pouring. 

Learn how to take a reliable impression

Models:

  • Plaster or stone models are acceptable. Generally, the durability of stone is preferred.
  • Models should be reasonably trimmed, yet sufficiently thick for strength considerations.
  • No horseshoe-shaped models; Models should have a base of at least 7mm in the thinnest area.
  • Bases will be added as necessary (for an additional fee) to models without bases or those lacking adequate base thickness or strength.
  • Please indicate if your model must be duplicated as work models may get damaged during the appliance fabrication process.

Bite Records:

  • Please package bite registrations carefully.
  • Bite records must not be left between models for shipment to the lab.
  • Dedicated packaging should be considered for brittle materials such as Delar wax.
  • Please identify the nature and the intent of each bite record, if more than one is being supplied.
  • Please consider mounting the maxillary model, before sending it to the lab, for those cases requiring mounting. Sending items such as facebows, bite forks, and mounting jigs through the mail often results in unreliable mountings.

Articulators:

We use the following articulators and their accessories in our laboratory:

  • SAM® 1, SAM® 2, SAM® 3 
  • Denar®
  • Panadent
  • Whip Mix
  • Hanau™
  • Stratos 200
  • Artex®
  • Kavo

Wear Times

Full Time

Appliance Warranty

90 Days